logo
Found 719 results for "

data center uninterruptible power supply

"
품질 연구실 서버실 및 데이터 센터용 설치 바닥 서식 산업용 에어컨 공장

연구실 서버실 및 데이터 센터용 설치 바닥 서식 산업용 에어컨

Product Description Specification CategoryCooling onlyIndoor unit modelEFA008C1Y0AEFA013C1Y0AOutdoor unit modelECA012ECA019Energy efficiency ratio3.63.45Power Specifications380VAC/50HZIndoor unit maximum current7A12AOutdoor unit maximum current0.85A1.7ARecommended input circuit breaker16A/4P16A/4PIndoor unit cable (recommended)5*2.5mm²5*2.5mm²Outdoor unit cable (recommended)3*1mm²Inner and outer unit signal cables (recommended)noneCooling capacity (kW)813Sensible cooling

품질 고 정밀 산업용 에어컨 8KW 13KW 데이터 센터 서버 룸 공장

고 정밀 산업용 에어컨 8KW 13KW 데이터 센터 서버 룸

Product Description Specification CategoryCooling onlyIndoor unit modelEFA008C1Y0AEFA013C1Y0AOutdoor unit modelECA012ECA019Energy efficiency ratio3.63.45Power Specifications380VAC/50HZIndoor unit maximum current7A12AOutdoor unit maximum current0.85A1.7ARecommended input circuit breaker16A/4P16A/4PIndoor unit cable (recommended)5*2.5mm²5*2.5mm²Outdoor unit cable (recommended)3*1mm²Inner and outer unit signal cables (recommended)noneCooling capacity (kW)813Sensible cooling

품질 높은 안전 수준 비센치 CRA 12.5KW 25KW 40KW 50KW 60KW 데이터 센터용 산업 정밀 에어컨 공장

높은 안전 수준 비센치 CRA 12.5KW 25KW 40KW 50KW 60KW 데이터 센터용 산업 정밀 에어컨

CRA series room-level precision air conditioner technical parameters and configuration table (row level)Air conditioner typeSingle cooling typeConstant temperature and humidity typeIndoor unit modelCRA025HAIT00CRA025HAITNNCRA040HAITNNOutdoor unit modelECA033ECA033ECA033Energy efficiency ratio2.82.83.02Power Specifications380VAC/50HZMaximum current20A23.6A40ARecommended input space32A/4P40A/4P64A/4PCooling capacity (kw)252540.3Sensible cooling capacity (kw)252540.3sensible

품질 5000m3/h 비센치 CRA 12.5KW 서버실 정밀 에어컨 연구실 데이터 센터 공장

5000m3/h 비센치 CRA 12.5KW 서버실 정밀 에어컨 연구실 데이터 센터

CRA series room-level precision air conditioner technical parameters and configuration table (row level)Air conditioner typeSingle cooling typeConstant temperature and humidity typeIndoor unit modelCRA025HAIT00CRA025HAITNNCRA040HAITNNOutdoor unit modelECA033ECA033ECA033Energy efficiency ratio2.82.83.02Power Specifications380VAC/50HZMaximum current20A23.6A40ARecommended input space32A/4P40A/4P64A/4PCooling capacity (kw)252540.3Sensible cooling capacity (kw)252540.3sensible

품질 비센치 CRA 12.5KW 25KW 40KW 50KW 60KW 실험실 데이터 센터용 실내용 공기 냉각 정밀 에어컨 공장

비센치 CRA 12.5KW 25KW 40KW 50KW 60KW 실험실 데이터 센터용 실내용 공기 냉각 정밀 에어컨

CRA series room-level precision air conditioner technical parameters and configuration table (row level)Air conditioner typeSingle cooling typeConstant temperature and humidity typeIndoor unit modelCRA025HAIT00CRA025HAITNNCRA040HAITNNOutdoor unit modelECA033ECA033ECA033Energy efficiency ratio2.82.83.02Power Specifications380VAC/50HZMaximum current20A23.6A40ARecommended input space32A/4P40A/4P64A/4PCooling capacity (kw)252540.3Sensible cooling capacity (kw)252540.3sensible

품질 비센치 위너 프로 1KR 랙 OEM UPS 1KVA 1KW 1000W 1단계 온라인 UPS 데이터 센터 공장

비센치 위너 프로 1KR 랙 OEM UPS 1KVA 1KW 1000W 1단계 온라인 UPS 데이터 센터

Product nameWinner Pro RackRated Capacity1KVA -10KVAPower Factor0.99Input Voltage208/220/230/240VACFrequency40Hz-70HzOutput Voltage208/220/230/240VACWaveformPure Sine waveBattery Type12V/9AHPHASESingle phase with grounHarmonic Distortion≤ 3 % THD (Linear Load),Harmonic DistortionCurrent Crest Ratio3:01Voltage Regulatior土1%Frequency Range47~ 53 Hz or 57~ 63 HzInverter to Bypass4 ms (Typical)Typical Recharge Time4 hours recover to 90% capacitySize(mm)310x438x88/410x438x88

품질 비센치 60KVA 80KVA 100KVA 120KVA 180KVA 200KVA 240KVA 300KVA 데이터 센터용 3단계 온라인 UPS 공장

비센치 60KVA 80KVA 100KVA 120KVA 180KVA 200KVA 240KVA 300KVA 데이터 센터용 3단계 온라인 UPS

Product nameFortress 3p3pRated Capacity60KVA-300KVAPower Factor0.99Input Voltage3 x 38014001415 VAC (3Ph+N)Frequency40Hz ~70HzOutput Voltage3 x 38014001415 VAC (3Ph+N)IP ClassIP20Battery TypeExternal BatteryPHASE3-phase in / 3-phase outHarmonic Distortion≤ 2% THD (Linear Load);≤ 4% THD (Non-linear Load)Temperature CompensationYesBattery Mode94.50%Frequency Range46Hz~ 54Hz or 56Hz~ 64HZAltitude**150%for 200msBATTERY/CHARGERNominal Voltage+/-192V~+1-240V (Selectable)Maximum

품질 10KVA-40KVA 등급 용량 데이터 센터용 위센치 갈레온 ll 3단계 타워 UPS 공장

10KVA-40KVA 등급 용량 데이터 센터용 위센치 갈레온 ll 3단계 타워 UPS

MODEL10K(L)15K(L)20K(L)30KL40KLPHASE3-phase in/3-phase outCAPACITY10KVA/10KW15KVA/15KW20KVA/20KW30KVA/30KW40KV /40KWINPUTHominsl Voltage3x208/220 VAC(Ph-Ph) 3x120/127 VAC (Ph-N)Voltage Range138~270 VAC(3-phase)@50%load;173~253 VAC(3-phase)@100%load 80~156 VAC(Ph-N) 50%load;100~148 VAC(Ph-N)@100%loadFrequency Range46~54 Hz or 56~64HzPower Factor≥0.99 @100%LoadOUTPUTQuput Voltage3x208/220 VAC(Ph-Ph) 3x120/127 VAC(Ph-N)AC Voltage Regulation (Batt.Mode)±1%Frequency Range

품질 30KVA 30KW 30000W 30000VA 데이터 센터 비센치 갈레온 III를 위한 순수 시노스 웨이브 온라인 업 공장

30KVA 30KW 30000W 30000VA 데이터 센터 비센치 갈레온 III를 위한 순수 시노스 웨이브 온라인 업

Product nameGalleon III 3p3pRated Capacity10KVA-40KVAPower Factor0.99Input Voltage3 x 360/380/400/415 VAC(3Ph+N)Frequency40~70 HZOutput Voltage3 x 360*1380*/400/415 VAC (3Ph+N)WaveformPure Sine waveBattery Type12V/9AhPHASE3Ph in/ 3Ph out or 3Ph in 1Ph out or 1Ph in 1Ph outHarmonic Distortion≤ 2% THD (Linear Load) ;≤ 5 % THD (Non-inear Load)Current Crest Ratio3:1(max.)Battery Mode94.50%Frequency Range46~54Hz or 56~64HzInverter to BypassZeroOperating Temperature0-40°CSize(mm