data center uninterruptible power supply
"
연구실 서버실 및 데이터 센터용 설치 바닥 서식 산업용 에어컨
Product Description Specification CategoryCooling onlyIndoor unit modelEFA008C1Y0AEFA013C1Y0AOutdoor unit modelECA012ECA019Energy efficiency ratio3.63.45Power Specifications380VAC/50HZIndoor unit maximum current7A12AOutdoor unit maximum current0.85A1.7ARecommended input circuit breaker16A/4P16A/4PIndoor unit cable (recommended)5*2.5mm²5*2.5mm²Outdoor unit cable (recommended)3*1mm²Inner and outer unit signal cables (recommended)noneCooling capacity (kW)813Sensible cooling
고 정밀 산업용 에어컨 8KW 13KW 데이터 센터 서버 룸
Product Description Specification CategoryCooling onlyIndoor unit modelEFA008C1Y0AEFA013C1Y0AOutdoor unit modelECA012ECA019Energy efficiency ratio3.63.45Power Specifications380VAC/50HZIndoor unit maximum current7A12AOutdoor unit maximum current0.85A1.7ARecommended input circuit breaker16A/4P16A/4PIndoor unit cable (recommended)5*2.5mm²5*2.5mm²Outdoor unit cable (recommended)3*1mm²Inner and outer unit signal cables (recommended)noneCooling capacity (kW)813Sensible cooling
높은 안전 수준 비센치 CRA 12.5KW 25KW 40KW 50KW 60KW 데이터 센터용 산업 정밀 에어컨
CRA series room-level precision air conditioner technical parameters and configuration table (row level)Air conditioner typeSingle cooling typeConstant temperature and humidity typeIndoor unit modelCRA025HAIT00CRA025HAITNNCRA040HAITNNOutdoor unit modelECA033ECA033ECA033Energy efficiency ratio2.82.83.02Power Specifications380VAC/50HZMaximum current20A23.6A40ARecommended input space32A/4P40A/4P64A/4PCooling capacity (kw)252540.3Sensible cooling capacity (kw)252540.3sensible
5000m3/h 비센치 CRA 12.5KW 서버실 정밀 에어컨 연구실 데이터 센터
CRA series room-level precision air conditioner technical parameters and configuration table (row level)Air conditioner typeSingle cooling typeConstant temperature and humidity typeIndoor unit modelCRA025HAIT00CRA025HAITNNCRA040HAITNNOutdoor unit modelECA033ECA033ECA033Energy efficiency ratio2.82.83.02Power Specifications380VAC/50HZMaximum current20A23.6A40ARecommended input space32A/4P40A/4P64A/4PCooling capacity (kw)252540.3Sensible cooling capacity (kw)252540.3sensible
비센치 CRA 12.5KW 25KW 40KW 50KW 60KW 실험실 데이터 센터용 실내용 공기 냉각 정밀 에어컨
CRA series room-level precision air conditioner technical parameters and configuration table (row level)Air conditioner typeSingle cooling typeConstant temperature and humidity typeIndoor unit modelCRA025HAIT00CRA025HAITNNCRA040HAITNNOutdoor unit modelECA033ECA033ECA033Energy efficiency ratio2.82.83.02Power Specifications380VAC/50HZMaximum current20A23.6A40ARecommended input space32A/4P40A/4P64A/4PCooling capacity (kw)252540.3Sensible cooling capacity (kw)252540.3sensible
비센치 위너 프로 1KR 랙 OEM UPS 1KVA 1KW 1000W 1단계 온라인 UPS 데이터 센터
Product nameWinner Pro RackRated Capacity1KVA -10KVAPower Factor0.99Input Voltage208/220/230/240VACFrequency40Hz-70HzOutput Voltage208/220/230/240VACWaveformPure Sine waveBattery Type12V/9AHPHASESingle phase with grounHarmonic Distortion≤ 3 % THD (Linear Load),Harmonic DistortionCurrent Crest Ratio3:01Voltage Regulatior土1%Frequency Range47~ 53 Hz or 57~ 63 HzInverter to Bypass4 ms (Typical)Typical Recharge Time4 hours recover to 90% capacitySize(mm)310x438x88/410x438x88
비센치 60KVA 80KVA 100KVA 120KVA 180KVA 200KVA 240KVA 300KVA 데이터 센터용 3단계 온라인 UPS
Product nameFortress 3p3pRated Capacity60KVA-300KVAPower Factor0.99Input Voltage3 x 38014001415 VAC (3Ph+N)Frequency40Hz ~70HzOutput Voltage3 x 38014001415 VAC (3Ph+N)IP ClassIP20Battery TypeExternal BatteryPHASE3-phase in / 3-phase outHarmonic Distortion≤ 2% THD (Linear Load);≤ 4% THD (Non-linear Load)Temperature CompensationYesBattery Mode94.50%Frequency Range46Hz~ 54Hz or 56Hz~ 64HZAltitude**150%for 200msBATTERY/CHARGERNominal Voltage+/-192V~+1-240V (Selectable)Maximum
10KVA-40KVA 등급 용량 데이터 센터용 위센치 갈레온 ll 3단계 타워 UPS
MODEL10K(L)15K(L)20K(L)30KL40KLPHASE3-phase in/3-phase outCAPACITY10KVA/10KW15KVA/15KW20KVA/20KW30KVA/30KW40KV /40KWINPUTHominsl Voltage3x208/220 VAC(Ph-Ph) 3x120/127 VAC (Ph-N)Voltage Range138~270 VAC(3-phase)@50%load;173~253 VAC(3-phase)@100%load 80~156 VAC(Ph-N) 50%load;100~148 VAC(Ph-N)@100%loadFrequency Range46~54 Hz or 56~64HzPower Factor≥0.99 @100%LoadOUTPUTQuput Voltage3x208/220 VAC(Ph-Ph) 3x120/127 VAC(Ph-N)AC Voltage Regulation (Batt.Mode)±1%Frequency Range
30KVA 30KW 30000W 30000VA 데이터 센터 비센치 갈레온 III를 위한 순수 시노스 웨이브 온라인 업
Product nameGalleon III 3p3pRated Capacity10KVA-40KVAPower Factor0.99Input Voltage3 x 360/380/400/415 VAC(3Ph+N)Frequency40~70 HZOutput Voltage3 x 360*1380*/400/415 VAC (3Ph+N)WaveformPure Sine waveBattery Type12V/9AhPHASE3Ph in/ 3Ph out or 3Ph in 1Ph out or 1Ph in 1Ph outHarmonic Distortion≤ 2% THD (Linear Load) ;≤ 5 % THD (Non-inear Load)Current Crest Ratio3:1(max.)Battery Mode94.50%Frequency Range46~54Hz or 56~64HzInverter to BypassZeroOperating Temperature0-40°CSize(mm